红联Linux门户
Linux帮助

linux 的几个常用文件

发布时间:2008-03-14 10:24:58来源:红联作者:itchinax
1. 使用vi /etc/grub.conf打开grub.conf配置文件,可以看到

# grub.conf generated by anaconda
#
# Note that you do not have to rerun grub after making changes to this file
# NOTICE: You have a /boot partition. This means that
# all kernel and initrd paths are relative to /boot/, eg.
# root (hd0,0)
# kernel /vmlinuz-version ro root=/dev/VolGroup00/LogVol00
# initrd /initrd-version.img
#boot=/dev/sda
default=0
timeout=5
splashimage=(hd0,0)/grub/splash.xpm.gz
hiddenmenu
title Red Hat Enterprise Linux Server (2.6.18-53.el5xen)
root (hd0,0)
kernel /xen.gz-2.6.18-53.el5 crashkernel=128M@16M
module /vmlinuz-2.6.18-53.el5xen ro root=/dev/VolGroup00/LogVol00 rhgb quiet
module /initrd-2.6.18-53.el5xen.img
title Red Hat Enterprise Linux Server-base (2.6.18-53.el5)
root (hd0,0)
kernel /vmlinuz-2.6.18-53.el5 ro root=/dev/VolGroup00/LogVol00 rhgb quiet
Type :quit to exit Vim
该目录的主要修改项为
default=0(默认的启动系统)
timeout=5(引导时间的设置)

2.使用 more /etc/initab命令进行系统启动的配置
#
# inittab This file describes how the INIT process should set up
# the system in a certain run-level.
#
# Author: Miquel van Smoorenburg, <miquels@drinkel.nl.mugnet.org>
# Modified for RHS Linux by Marc Ewing and Donnie Barnes
#

# Default runlevel. The runlevels used by RHS are:
# 0 - halt (Do NOT set initdefault to this)
# 1 - Single user mode
# 2 - Multiuser, without NFS (The same as 3, if you do not have networking)
# 3 - Full multiuser mode
# 4 - unused
# 5 - X11
# 6 - reboot (Do NOT set initdefault to this)
#
id:5:initdefault:

# System initialization.
si::sysinit:/etc/rc.d/rc.sysinit

l0:0:wait:/etc/rc.d/rc 0
l1:1:wait:/etc/rc.d/rc 1
l2:2:wait:/etc/rc.d/rc 2
l3:3:wait:/etc/rc.d/rc 3
l4:4:wait:/etc/rc.d/rc 4
l5:5:wait:/etc/rc.d/rc 5
l6:6:wait:/etc/rc.d/rc 6

# Trap CTRL-ALT-DELETE
ca::ctrlaltdel:/sbin/shutdown -t3 -r now

# When our UPS tells us power has failed, assume we have a few minutes
# of power left. Schedule a shutdown for 2 minutes from now.
# This does, of course, assume you have powerd installed and your
# UPS connected and working correctly.
pf::powerfail:/sbin/shutdown -f -h +2 "Power Failure; System Shutting Down"

# If power was restored before the shutdown kicked in, cancel it.
pr:12345:powerokwait:/sbin/shutdown -c "Power Restored; Shutdown Cancelled"


# Run gettys in standard runlevels
1:2345:respawn:/sbin/mingetty tty1
2:2345:respawn:/sbin/mingetty tty2
3:2345:respawn:/sbin/mingetty tty3
4:2345:respawn:/sbin/mingetty tty4
5:2345:respawn:/sbin/mingetty tty5
6:2345:respawn:/sbin/mingetty tty6

# Run xdm in runlevel 5
x:5:respawn:/etc/X11/prefdm -nodaemon

3. /etc/sysconfig/network
可以看到下列参数:
NETWORKING=yes
NETWORKING_IPV6=no
HOSTNAME=localhost.localdomain
[root@localhost sysconfig]#
[root@localhost sysconfig]#
其中:
NETWORKING表示网络是否被配置
HOSTNAME 表示服务器的主机名
GETWAY表示网络网关的IP地址
FORWARD_IPV4表示是否开启IP转发的功能
GETWAYDEV表示网络设备名
文章评论

共有 1 条评论

  1. ch132123 于 2008-03-14 11:33:26发表:

    看不懂,难得很,学习